NJC3312A
S-band Circulator

Download Datasheet
  • Microwave products
  • RoHS
Product image1
Product image1

Description

Features

Frequency

  • 3030 to 3070 MHz

Input power (Peak)

  • 30 kW max.

Input power (Average)

  • 30 W max.

Duty cycle / Pulse duration

  • 0.001 / 1.0 μsec

Others

  • RoHS compliant

Spec

Items Parameters
Frequency 3030 to 3070 MHz
Duty cycle / Pulse duration 0.001 / 1.0 μsec
Input power (Peak) 30 kW max.
RF interface Waveguide: WR284
Isolation 17 dB min.
Insertion loss 0.5 dB max.
V.S.W.R. 1.3 max.
Weight 1.1 kg