Package support information
Soldering
This section provides information necessary for using semiconductor devices, including storage and cleaning conditions related to device mounting on a substrate, as well as reflow profiles. Please use it together with the product data sheet.
Soldering flux
Don’t use halogen-based soldering flux.
Please use RMA type and low residue type.
Heat-resistance profiles
-
Pb-Free Reflow profile
-
Dip soldering
MSL(Moisture Sensitivity Levels)
Our products are classified as follows. Though reflow process can be allowed up to 3 times, make sure to minimize the temperature and the exposure time.( Some products are limited up to 2 times.)
| Storage period | JEDEC | |
|---|---|---|
| LEVEL | Storage condition | |
| Unlimited | 1 | 30°C, 85% RH or less |
| 1 year (*) | 2 | 30°C, 60% RH or less |
| 4 weeks (*) | 2a | 30°C, 60% RH or less |
| 2 weeks (*) | - | - |
| 168 hours (*) | 3 | 30°C, 60% RH or less |
| 72 hours(*) | 4 | 30°C, 60% RH or less |
| 48 hours (*) | 5 | 30°C, 60% RH or less |
| 24 hours (*) | 5a | 30°C, 60% RH or less |
| Specified individually | 6 | 30°C, 60% RH or less |
(*) Baking: 125°C, 24 h
The board cleaning conditions.
-
Cleaning Conditions (Electronic device products)
- We recommend alternative CFCs substitute for solvent.
Don’t use trichloroethylene, trichloroethane, etc. - Cleaning time should be less than 180 s. (including in solvent, in vapor and in ultrasonic bath).
- Ultrasonic cleaning is available
Frequency : 28 to 40 kHz (Please avoid resonance.)
Power : 15 W/liter (MAX.)
Time : 60 s (MAX.)
(Note)The above cleaning conditions are just reference. Please confirm the following items too.
- Set the proper cleaning condition according to the recommendation of the cleaner manufacturer.
- Take notice that mark legibility can be degraded by cleaning.
- Please be careful not to remain corrosive constituents.
- We recommend alternative CFCs substitute for solvent.
-
Cleaning Conditions (Optoe-Electronic Devices)
- Please refrain from cleaning of the device as much as possible.
Be careful to a void solvents or the vapor of solvents attach the resin of devices even during the mounting and using. -
If cleaning flux and others is indispensable, lead parts of devices only can be cleaned by using the following solvent by the condition within 35℃ and 3minute.
Solvent : isopropyl alcohol, methyl alcohol - For products that support reflow soldering, avoid cleaning immediately after the reflow.
- Please refrain from cleaning of the device as much as possible.
Storage Condition
Notes of IC storage
- Do not use water for the tap for humidifiers, but use pure water or boiled water.
- Do not store devices in a corrosive-gas atmosphere.
- Do not store devices in a dusty place.
- Do not expose devices to direct sunlight.
- Maintain the temperature of the storage place stabilized.
- Keep away from excessive load and impact.
- Keep away from excessive electromagnetic radiation exposure.
Storage period
Please mount devices within a year after delivering. For the devices have stored longer than a year, check the corrosion of leads and solderability before using.
IC Storage Conditions for Normal Packing
-
Temperature and humidity ranges.
Temperature: 5 to 30 (℃)
Humidity : 30 to 85 (%)- Baking is unnecessary in the above mentioned storage conditions.
-
Moisture Sensitivity Levels
JEDEC: Level 1
IC Storage Conditions for Deaeration Packing
-
Temperature and humidity ranges.
Temperature before unpacking: 5 to 40 (℃)
Humidity : 30 to 90 (%)
Temperature after unpacking: 5 to 30 (℃)
Humidity : 30 to 60 (%)
Use devices within 4weeks (672h) after unpacking.- Baking is unnecessary in the above mentioned storage conditions.
-
Moisture Sensitivity Levels
JEDEC: Level 2a
IC Storage Conditions for Moisture-Proof Packing
-
Temperature and humidity ranges.
Temperature before unpacking: 5 to 40 (℃)
Humidity : 30 to 90 (%)
Temperature after unpacking: 5 to 30 (℃)
Humidity : 30 to 60 (%)
Be sure to use within 1weeks (168h) after the open the anti-humidity seal. -
Baking
If deviate from the above condition, be sure to apply baking. (Heat proof tray products)
Baking ConditionMethod: Ta=125ºC, more thanover 24h -
Moisture Sensitivity Levels
JEDEC: Level 3
FAQ
We have posted FAQs related to packages that are often received by customers.
Thermal resistance / Package outline drawing / Package notation / Recommended land pattern / Taping of reel shipment / etc.