NJU9102 Series
Digital Earth Leakage Current Detector IC
Ground Fault Current Detect IC
NJU9102 Series
Digital Earth Leakage Current Detector IC
Ground Fault Current Detect IC
Ground Fault Current Detect IC
- Download Datasheet
- ECAD Model: Learn more
-
拡大
:q

Description
NJU9102/A is a digital detector IC for earth leakage current breaker. The built-in ADC converts from an analog signal from ZCT (Zero-phase-sequence Current Transformer) to digital data, and processes digital data based on an earth leakage current detector condition. As a result of data processing, NJU9102/A outputs a one-shot pulse on SCRT terminal when an analog signal is judged to a leakage condition, and turns on an external thyristor.
Applications
- Earth Leakage Current Breaker
- GFCI (Ground Fault Current Interrupter)
Spec
Standard | |
---|---|
Supply Voltage | 4V to 5.5V |
Operating Current | Typ. 300μA |
Internal Power Supply | VREG=3.3V/ VCOM=1.65V |
Resolution | 14 |
Number of Pin | 8 |
Structure | CMOS Technology |
Wide Operating Temperature | -40℃ to +105℃ |
Junction Temp. | +150℃ |
Package | DMP8 |
Built-in High Precision ADC | 14-Bit |
Sinc3 Digital Filter | -3dB Frequency = 150Hz |
Earth Leakage Detector Condition (TMD) | Type A / Type AC switchable |
Five times trip level detection | NJU9102: Immediate response NJU9102A: No immediate response |
Control Circuit | Earth Leakage Detector Condition (TMD) Sampling Counter (SCRT) |
Technical Documents
Quality & Packages
Product Name | Compatibility | Package | Marking | Reliability |
---|---|---|---|---|
NJU9102M |
|
DMP8 | - | NJU-1-s-fr |
- Refer to the datasheets for the details on the product.
- The package file or the datasheet includes package dimensions, taping specifications, taping reels dimensions, power dissipations, and recommended land pattern.