Does the input voltage of NJU7108 operate at the following conditions?
Does the input voltage of NJU7108 operate at the following conditions?
Comparator
Does the input voltage of NJU7108 operate at the following conditions?
+INPUT: 1.5V,
–INPUT: 0 to 3V,
V+ = 3V, V- = 0V, Ta = 25°C
Comparator operates when one of the input terminals is applied within common mode input voltage range and the other input terminal is applied higher than common mode input voltage range.
(*) input voltage is within supply voltage. NJU7108 (*) operates normally when it uses at this condition.
Because, +INPUT terminal is applied within common mode input voltage range and -INPUT terminal is applied within supply voltage.
(*) common mode input voltage range of NJU7108 is 0 to 2.5V @V+=3V, V-=0V, Ta=25°C
Related Products
If you still have questions.
-
Search Other FAQs
-